Figure 8. Cab Instrument Panel - Center Console (Sheet 1 of 3)
Figure 8. Cab Instrument Panel - Center Console (Sheet 3 of 3)

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  29    30    31    32    33  34  35    36    37    38    39  
img
DRAFT
TM 5-4210-249-13&P-1
0004
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT00423AP
Figure 8.
Cab Instrument Panel - Center Console (Sheet 2 of 3).
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Key
Control or Indicator
Function
Fig. 8
3
WARNING BUZZER
Provides audible warning to the driver from rear step buzzer.
Buzzer sounds once to STOP, twice to GO, and three times to
BACKUP.
4
Warning Indicator Light
Light illuminates once to tell the driver to stop, twice to go, and
three times to back-up.
5
MODE Switch
Press to select operating mode.
6
PRESSURE LED
Illuminates when in PRESSURE mode.
7
RPM LED
Illuminates when in RPM mode.
8
IDLE Switch
Press to return water pump engine to idle.
9
PRESET Switch
Press after an operating mode has been chosen, to promptly bring
engine or pump RPM to a preset pressure.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -