FINAL INSPECTION
c. Inspect the test set container to insure that the clasp
5-1. General.
fasteners secure the lid firmly to the bottom section and
that the seal between the two sections is undamaged.
References to tests and procedures for final inspection
of the fire control subsystem test set after repairs have been
5-3. Other Components.
completed are provided in this chapter. If no deficiencies
In accordance with the procedures of paragraph 4-3,
are found, the test set is ready to be returned to the user or
inspect the LOD, the helmet boresight tool, the circuit card
to stock.
extractor, the connector shorting assembly, and the four
cables, all of which are stored in the lid of the test set
container. Give special attention to the borescope angle
bracket of the LOD to insure that it is not bent or twisted
out of alignment.
a. V i s u a l l y i n s p e c t t h e t e s t s e t s u b a s s e m b l y i n
accordance with the procedures in paragraph 4-3.
Inspect in accordance with the procedures of paragraph
|