Click here to make tpub.com your Home Page

Page Title: Mount Rigidity Inspection - continued
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-1240-375-34&P
0073 00
7
8
1 fc 4 7 4
4.
Rotate azimuth knob (7) clockwise to 4800 mils on azimuth counter (8). Align target to reticle line.
10
9
1 fc 4 7 5
5.
While sighting optical instrument support (9) on target, use push-pull gage (10), and apply 20-lb
(9.07 kg) load on right side, 2.3 in. (5.84 cm) from center of optical instrument support.
6.
Release load and record amount of movement.
7.
Place push-pull gage (10) on left side of optical instrument support (9), and apply 20-lb (9.07 kg) load,
2.3 in. (5.84 cm) from center of optical instrument support.
8.
Release load and record amount of movement.
9.
Total of steps 6 and 8 must not exceed total movement listed in Table 1.
NOTE
If movement exceeds amount allowed in Table 1, recheck M171/M171A1 mount for
proper assembly. If movement still exceeds amount allowed in Table 1, return to
depot maintenance.
10.
Repeat steps 1 through 9 using elevations listed in Table 1.
0073 00-33

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business