TM 9-1240-375-34&P
GENERAL SUPPORT
M17/M18 FIRE CONTROL QUADRANT
(1290-01-037-3883/1290-01-037-7289)
FIRE CONTROL LEVEL ASSEMBLY (ELEVATION LEVEL VIAL ASSEMBLY) MAINTENANCE
REMOVAL, DISASSEMBLY, REPAIR OR REPLACEMENT, ASSEMBLY, INSTALLATION, ADJUSTMENT
INITIAL SETUP:
Test Equipment
Mounting bracket (item 2, WP 0149 00)
Optical equipment test fixture (item 8, WP 0149 00)
Plate-mounted level (item 12, WP 0149 00)
Tools and Special Tools
Tool Kit, Electronic System Maintenance (SC 5180-95-B29)
Materials/Parts
Lockwasher (4) (item 4, WP 0111 00)
Lock wire (item 21, WP 0152 00)
Plastic bag (item 5, WP 0152 00)
Sealing compound (item 13, WP 0152 00)
Tape (item 20, WP 0152 00)
References
REMOVAL
WARNING
TRITIUM
GAS (H3)
When maintaining radioactively illuminated fire control equipment, follow radiation
hazard procedures in warning summary.
NOTE
General support maintenance instructions for the M18 quadrant fire control level
assembly are identical to the M17 quadrant fire control level assembly.
0051 00-1
|