TM 9-1240-375-34&P
0050 00
33.
Connect connector (40) on cover assembly (39) to connector (41) on housing assembly (2).
34.
Apply sealing compound (item 13, WP 0152 00) to threads of seven machine screws (42).
CAUTION
Use extreme care during assembly. Do not pinch wires or connectors between parts.
35.
Install cover assembly (39) and O-ring (38) on housing assembly (2) with seven new lockwashers (43)
(item 18, WP 0111 00) and seven machine screws (42).
36.
Install plug (44) to cover assembly (39).
37.
Install battery enclosure and gasket. Refer to WP 0047 00.
38.
Purge and charge with dry nitrogen. Refer to TM 750-116.
39.
Perform adjustment of fire control level assembly. Refer to WP 0048 00.
END OF WORK PACKAGE