TM 9-1240-375-34&P
DIRECT SUPPORT
M137/M137A2/M137A3 PANORAMIC TELESCOPE
(1240-01-038-0531/1240-01-483-6103/1240-01-483-6100)
TROUBLESHOOTING PROCEDURES
OPTICAL ELEMENTS
INITIAL SETUP:
Materials/Parts
Battery (2) (item 8, WP 0152 00)
Plastic bag (item 5, WP 0152 00)
Tape (item 20, WP 0152 00)
References
OPTICAL ELEMENTS
Table 1. Troubleshooting Procedures.
WARNING
TRITIUM
GAS (H3)
When maintaining radioactively illuminated fire control equipment, follow radiation
hazard procedures in warning summary.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. RETICLE DOES NOT
Visually inspect in darkened
1. Contact RSO immediately.
ILLUMINATE OR HAS
area.
UNEVEN ILLUMINATION
2. Perform wipe test under RSO
(M137).
supervision.
3. Remove, bag, and secure
device under RSO direction
and await wipe test results.
4. If contaminated, dispose of
device per RSO instructions.
5. If device is not contaminated,
evacuate to depot for
maintenance.
0036 00-1
|