TM 9-1240-375-34&P
0036 00
OPTICAL ELEMENTS - Continued
Table 1. Troubleshooting Procedures - Continued.
WARNING
Read and follow all WARNINGS in the WARNING SUMMARY in the front of this
manual. Pay careful attention to those concerning batteries.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. RETICLE DOES NOT
Observe visually in darkened
1. Replace batteries (item 8, WP
ILLUMINATE (M137A2/
area.
0152 00) in panoramic
M137A3).
telescope.
a. Unscrew battery caps.
b. Remove batteries using
magnet in battery cap.
c. Install new batteries in
same direction as diagram
on battery enclosure.
d. Replace battery caps.
2. Replace battery enclosure
assembly (4) (WP 0084 00).
3. Replace light source adapter
assembly (WP 0084 00).
4. Notify general support
maintenance.
3. RETICLE AND IMAGE
Visually inspect.
Notify general support
HAVE PARALLAX.
maintenance.
Notify general support
4. INTERNAL OPTICS ARE
1. Inspect seal between head
maintenance.
FOGGED OR HAVE
assembly and body assembly.
Notify general support
2. Inspect seal between body
maintenance.
assembly and elbow
assembly.
END OF WORK PACKAGE