TM 9-1240-375-34&P
0009 00
Table 1. Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Observe visually in darkened
1. Contact RSO immediately.
2. ELEVATION LEVEL VIAL
area.
(1), CROSS LEVEL VIAL
2. Perform wipe test under
(2), AND COUNTER DIALS
RSO supervision.
(3) HAVE UNEVEN OR NO
3. Remove, bag, and secure
device under RSO direction
and await wipe test results.
4. If contaminated, dispose of
device per RSO instructions.
5. If device is not contaminated,
replace elevation level vial
6. If device is not contaminated,
replace cross level vial
7. If device is not contaminated,
send to depot for replacement
of tritium that illuminates the
counter.
8. Dispose of replaced vial per
RSO instructions.
Observe visually.
1. Contact RSO immediately.
3. ELEVATION LEVEL VIAL
(1) AND CROSS LEVEL
2. Perform wipe test under RSO
VIAL (2) HAVE NO
supervision.
BUBBLE, BUT ARE STILL
3. Remove, bag, and secure
ILLUMINATED.
device under RSO direction
and await wipe test results.
4. If contaminated, dispose of
device per RSO instructions.
5. If device is not contaminated,
replace elevation level vial
6. If device is not contaminated,
replace cross level vial
7. Dispose of replaced vial per
RSO instructions.
0009 00-3