HYDRAULIC GENERATOR CABLES REPLACEMENT
HYDRAULIC GENERATOR CABLES REPLACEMENT - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 4 Page Navigation
  135    136    137    138    139  140  141    142    143    144    145  
img
DRAFT
TM 5-4210-249-13&P-4
0583
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT00313C
4.
Remove four locknuts (7), eight washers (8), four screws (9), and air conditioning fan assembly (10) from
hydraulic generator cover (11), and move air conditioning assembly (10) out of the way. Discard locknuts.
5.
Remove ten screws (12), washers (13), and hydraulic generator cover (11) from hydraulic generator (14).
6.
Remove four screws (15) and access cover (16) from electrical box (17).
TFFT00313B
NOTE
Tag and mark wires prior to removal to ensure proper installation.
Remove cable ties and cushion clips as required.
7.
Remove nut (18) and wire (19) from stud (20).
8.
Remove nut (21) and wire (22) from stud (23) and pull wire (22) through current transformer (24).