0583
INSTALLATION
NOTE
Install wires in same position as noted prior to removal
1.
Feed four wires (31), (26), (22), and (19) through two panels (50) and (49) and position on vehicle.
2.
Install cover (48) on vehicle with two screws (47).
3.
Install grommet (46), stopper (45), and collar (44) on four wires (31), (26), (22), and (19).
4.
Install four wires (31), (26), (22), (19), and collar (44) on breaker box (35).
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT00314B
5.
Install wire (19) on bus bar (43) and tighten screw (42).
6.
Install wire (31) on bus bar (41) and tighten screw (40).
7.
Install wire (26) on breaker (39) and tighten screw (38).
8.
Install wire (22) on breaker (37) and tighten screw (36).