DRAFT
TM 5-4210-249-13&P-4
FIELD LEVEL MAINTENANCE
WINDSHIELD DELUGE SHUTOFF VALVE AND STRAINER ASSEMBLY REPLACEMENT
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Tools and Special Tools
References
Tool Kit, General Mechanic's: Automotive
WP 0483
Materials/Parts
Equipment Conditions
Water pump engine air cleaner assembly
Item 21)
removed (WP 0220)
Water system drained (WP 0041)
Pump house panel Q removed (WP 0540)
Lockwasher (1)
REMOVAL
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT00853
NOTE
Remove cable ties as required.
Tag and mark hoses prior to removal to ensure proper installation.
Moving pipe and hose allows for easier removal of window deluge shutoff valve.
1.
Remove three couplings (1), (2), and (3) and pipe (4) from vehicle (WP 0483).
2.
Remove coupling (5) from hose (6) and pipe (7), and move hose (6) upwards (WP 0483).
3.
Disconnect connector (8).
0582-1