WINDSHIELD DELUGE PUMP HOUSE STRAINER SCREEN REPLACEMENT
WINDSHIELD DELUGE SYSTEM REPLACEMENT

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 3 Page Navigation
  1301    1302    1303    1304    1305  1306  1307    1308    1309    1310    1311  
img
.
DRAFT
TM 5-4210-249-13&P-3
0561
INSTALLATION
TFFT00721
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WARNING
ICON 30, 44, 27
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing. To avoid injury or death, keep away
from open fire and use in well-ventilated area. If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
CAUTION
Use sealing compound sparingly only on pipe threads. Do not apply compound to
hose connections. Damage to equipment may result.
1.
Apply sealing compound to threads of plug (5).
2.
Install plug (5) on cap (1).
CAUTION
Do not damage screen when positioning screen in cap and strainer. Failure to
comply may result in damage to screen.
3.
Install screen (3), gasket (2), and cap (1) on strainer (4).
END OF TASK
FOLLOW-ON MAINTENANCE
Close pump house panel A (WP 0539)
END OF TASK
END OF WORK PACKAGE