30. Place gasket (34) on transmission (25).
NOTE
PTO and PTO pump are installed as an assembly.
31. With the aid of an assistant, install PTO (33) and PTO pump (35) on transmission (25) with eight screws (32).
Tighten screws to 42 to 50 lb.-ft. (57 to 68 Nm).
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WARNING
ICON 30, 44, 27
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing. To avoid injury or death, keep away
from open fire and use in well-ventilated area. If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
32. Apply sealant to eight screws (32) to mark torque point.
33. Install hose (30) on elbow (31).
34. Install hose (28) on elbow (29).
35. Install hose (26) on fitting (27).
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
0558-18