PUMP HOUSE PANELS REPLACEMENT - Continued
PUMP HOUSE PANELS REPLACEMENT - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 3 Page Navigation
  1173    1174    1175    1176    1177  1178  1179    1180    1181    1182    1183  
img
.
DRAFT
TM 5-4210-249-13&P-3
0540
PUMP PANEL L INSTALLATION
TFFT00236
1.
Install rubber guard (26) on pump panel L (5).
2.
Install three decal plates (25) on pump panel L (5) (WP 0518).
3.
Install pump panel L (5) on vehicle with three washers (24), lockwashers (23), and screws (22).
4.
Install box (21) and receptacle (19) on pump panel L (5) with screw (20).
5.
Install receptacle (19) on pump panel L (5) with washer (18) and screw (17).
6.
Install gasket (16) and receptacle cover (15) on pump panel L (5) with four washers (14) and screws (13).
7.
Install two gaskets (12) and cover plates (11) on pump panel L (5) with eight washers (10) and screws (9).
8.
Install two couplings (7) on passenger side discharge pipes (8).
9.
Install two caps (6) on couplings (7).
10. Install two clips (4) on pump panel L (5) with two washers (3), lockwashers (2), and screws (1).
END OF TASK
0540-19