PUMP HOUSE PANELS REPLACEMENT - Continued
PUMP HOUSE PANELS REPLACEMENT - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 3 Page Navigation
  1172    1173    1174    1175    1176  1177  1178    1179    1180    1181    1182  
img
. .
DRAFT
TM 5-4210-249-13&P-3
0540
PUMP PANEL K INSTALLATION
1.
Install pump house access door (6) on pump panel K (5) (WP 0538).
2.
Install pump panel K (5) on vehicle with four washers (4), lockwashers (3), and screws (2).
3.
Install pump panel M (1).
END OF TASK
PUMP PANEL L REMOVAL
TFFT00236
1.
Remove two screws (1), lockwashers (2), washers (3), and clips (4) from pump panel L (5). Discard
lockwashers.
2.
Remove two caps (6) from couplings (7).
3.
Remove two couplings (7) from passenger side discharge pipes (8).
4.
Remove eight screws (9), washers (10), two cover plates (11), and gaskets (12) from pump panel L (5).
5.
Remove four screws (13), washers (14), receptacle cover (15), and gasket (16) from pump panel L (5).
6.
Remove screw (17) and washer (18) from receptacle (19) and pump panel L (5).
7.
Remove screw (20), receptacle (19), and box (21) from pump panel L (5).
8.
Remove three screws (22), lockwashers (23), washers (24), and pump panel L (5) from vehicle. Discard
lockwashers.
9.
Remove three decal plates (25) from pump panel L (5) (WP 0518).
10. Remove rubber guard (26) from pump panel L (5).
END OF TASK