PUMP OPERATOR'S PANEL WIRE HARNESS REPLACEMENT - Continued
PUMP OPERATOR'S PANEL WIRE HARNESS REPLACEMENT - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 3 Page Navigation
  725    726    727    728    729  730  731    732    733    734    735  
img
DRAFT
TM 5-4210-249-13&P-3
0459
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT03291
13. Remove two screws (46), lockwashers (47), wire 1405 (48), and wire 3895 (49) from overheat alarm
indicator (50). Discard lockwashers.
14. Remove two screws (51), lockwashers (52), wire 2773 (53), and wire 1590 (54) from overheat alarm test
switch (55). Discard lockwashers.
15. Disconnect pump operator's panel wire harness connector (56) from overheat audio alarm (57).
16. Cut wire 2341 (58) and wire 3895 (59) (TM 9-2320-325-14&P).
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT03292
17. Cut wire 2341 (60) and wire 3895 (61) (TM 9-2320-325-14&P).
18. Remove two screws (62), lockwashers (63), wire 2834 (64), and wire 4053 (65) from WATER TANK DRAIN
switch (66). Discard lockwashers.
19. Remove two screws (67), lockwashers (68), wire 4053 (69), and wire 3895 (70) from WATER TANK DRAIN
indicator (71). Discard lockwashers.
0459-6