DRAFT
TM 5-4210-249-13&P-3
0459
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT03287
8.
Disconnect pump operator's panel wire harness connector (30) from ENFO IV display module (31).
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT03288
NOTE
A wire with an H prefix indicates HEMTT wires.
9.
Remove three nuts (32), lockwashers (33), wire H076 (34), wire H318 (35), and wire 3895 (36) from fuel level
10. Disconnect light bulb socket connector (38) from fuel level gauge (37).
0459-4