CAB POWER DISTRIBUTION WIRE HARNESS AND BLOCK REPLACEMENT - Continued
CAB POWER DISTRIBUTION WIRE HARNESS AND BLOCK REPLACEMENT - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 3 Page Navigation
  533    534    535    536    537  538  539    540    541    542    543  
img
DRAFT
TM 5-4210-249-13&P-3
0441
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT03163
4.
Remove nut (14), lockwasher (15), and wire 2264 (16) from cab 12 VDC switched terminal block (17).
Discard lockwasher.
5.
Disconnect cab instrument panel wire harness connector MP1 (18) from cab power distribution wire harness
connector MP1 (19).
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT03164
6.
Remove nut (20), washer (21), and wire 2074 (22) from driver side 12 VDC auxiliary outlet (23).
7.
Disconnect wire 1640 (24) from driver side 12 VDC auxiliary outlet (23).