DRAFT
TM 5-4210-249-13&P-3
0427
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT02359A
11. Remove 14 fittings (15), (48), (16), (17), (18), (19), (20), (21), (22), (28), (29), (30), (31), and (32) from control
valve manifold (45).
END OF TASK
INSTALLATION
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WARNING
ICON 30, 44, 27
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing. To avoid injury or death, keep away
from open fire and use in well-ventilated area. If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
CAUTION
Use sealing compound sparingly only on pipe threads. Do not apply compound to
hose connections. Damage to equipment may result.
NOTE
Install cable ties as required.
1.
Apply sealing compound to threads of 14 fittings (32), (31), (30), (29), (28), (22), (21), (20), (19), (18), (17),
(16), (48), and (15).
2.
Install 14 fittings (32), (31), (30), (29), (28), (22), (21), (20), (19), (18), (17), (16), (48), and (15) on control valve
manifold (45).
0427-4