DRAFT
TM 5-4210-249-13&P-3
FIELD LEVEL MAINTENANCE
CORD REEL REWIND CIRCUIT BREAKER REPLACEMENT
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Tools and Special Tools
References
Tool Kit, General Mechanic's: Automotive
WP 0615, Fig. 77, 78
(WP 0622, Item 27)
Equipment Conditions
Materials/Parts
Water pump engine OFF (WP 0022)
Compound, Sealing (WP 0625, Item 17)
Batteries disconnected (TM 9-2320-325-14&P)
Tags, Identification (WP 0625, Item 51)
Locknut (2)
Locknut (2)
REMOVAL
TFFT04200
NOTE
Tag and mark wires prior to removal to ensure proper installation.
1.
Remove locknut (1), cord reel control wire (2), and high amperage cable (3) from cord reel rewind circuit
breaker (4). Discard locknut.
2.
Remove locknut (5) and wire 1296580 (6) from cord reel rewind circuit breaker (4). Discard locknut.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -