120-VOLT CIRCUIT BREAKER REPLACEMENT - Continued
120-VOLT CIRCUIT BREAKER REPLACEMENT - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 3 Page Navigation
  222    223    224    225    226  227  228    229    230    231    232  
img
DRAFT
TM 5-4210-249-13&P-3
0360
3.
Remove double circuit breaker (9) from bus bar (10) and bracket (11).
4.
Loosen screw (12) and remove two wires (13) and (14) from double circuit breaker (9).
NOTE
Perform Steps (5) and (6) for removal of all single circuit breakers.
Number of wires may vary. Note position and quantity before removal.
5.
Loosen screw (15) and remove wire (16) from single circuit breaker (17).
6.
Remove single circuit breaker (17) from bus bar (10) and bracket (11).
END OF TASK
INSTALLATION
NOTE
Perform Steps (1) through (3) for installation of all double circuit breakers.
1.
Install two wires (14) and (13) on double circuit breaker (9) and tighten screw (12).
2.
Install double circuit breaker (9) on bracket (11) and bus bar (10).
3.
Install two wires (8) and (7) on double circuit breaker (9) and tighten two screws (5) and (6).
NOTE
Perform Steps (4) and (5) for installation of all single circuit breakers.
4.
Install wire (16) on single circuit breaker (17) and tighten screw (15).
5.
Install single circuit breaker (17) on bracket (11) and bus bar (10).
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
0360-3