TM 5-4210-249-13&P-2
0176
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT04305
Step 15.
Disconnect pump operator's panel wire harness pump house wire harness connector.
With a test lead set, check for continuity across wire 1661 (black) from pump operator's
panel wire harness pump house panel wire harness connector, terminal 1 to
disconnected pump house wire harness work light connector, terminal A.
a.
If there is continuity, repair wire 1661 in pump operator's panel wire
harness if repairable (TM 9-2320-325-14&P), or replace pump
operator's panel wire (WP 0459).
b.
If there is no continuity, repair wire 1661 in pump house wire harness if
repairable (TM 9-2320-325-14&P), or replace pump house wire
harness (WP 0458).
Step 16.
Check if pump house work lights operate.
If pump house work lights do not operate, go to Step 18.
0176-10