PUMP HOUSE OR PUMP OPERATOR'S PANEL WORK LIGHT(S) DOES NOT OPERATE - Continued
DRIVER SIDE STOWAGE COMPARTMENT LIGHT(S) DOES NOT OPERATE

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 2 Page Navigation
  652    653    654    655    656  657  658    659    660    661    662  
img
DRAFT
TM 5-4210-249-13&P-2
0176
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT043010
Step 22.
Turn battery disconnect switch to OFF position (WP 0007). Remove skid plate grille
(WP 0550). Disconnect main wire harness main 2 wire harness connector. With a test
lead set, check for continuity across main wire harness wire 2346 (red) from main wire
harness main 2 wire harness connector, terminal B to main wire harness pump
operator's panel wire harness connector DO2, terminal 8.
a.
If there is continuity, repair wire 2346 in cab power distribution wire
harness if repairable (TM 9-2320-325-14&P), or replace cab power
distribution wire harness and block (WP 0441).
b.
If there is no continuity, repair wire 2346 in main wire harness if
repairable (TM 9-2320-325-14&P), or replace main wire
harness (WP 0455).
END OF TASK
FOLLOW-ON MAINTENANCE
Remove wheel chocks (TM 9-2320-347-10)
END OF TASK
END OF WORK PACKAGE
0176-15/(16 blank)