0176
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
WARNING
ICON 3
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle. Jewelry can catch on equipment and cause serious injury. Jewelry
and tools may short across electrical circuits and cause damage to equipment, or
severe burns or electrical shock to personnel.
Step 14.
Put pump operator's panel PANEL LIGHTS switch to off position (WP 0004). Turn
battery disconnect switch to OFF position (WP 0007). Disconnect any pump house
work light connector. With a test lead set, check for continuity across pump house wire
harness wire 1640 (black) from work light connector, terminal B to a known good
ground.
If there is no continuity, repair wire 1640 in pump house wire harness if
repairable (TM 9-2320-325-14&P), or replace pump house wire harness
(WP 0458).