HYDRAULIC GENERATOR OIL COOLING FAN DOES NOT OPERATE PROPERLY - Continued
INTERCOM AND HEADSETS DO NOT OPERATE PROPERLY

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 2 Page Navigation
  580    581    582    583    584  585  586    587    588    589    590  
img
DRAFT
TM 5-4210-249-13&P-2
0172
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT00731
Step 3.
Turn battery disconnect switch to OFF position (WP 0007). Check for continuity across
wire 1640 (black) from hydraulic generator oil cooler fan connector to a known good
ground.
a.
If there is continuity, replace hydraulic generator (WP 0592).
b.
If there is no continuity, repair wire 1640 (black) from hydraulic
generator oil cooler fan connector to ground if
repairable (TM 9-2320-325-14&P), or replace body air condenser wire
harness (WP 0436).
END OF TASK
FOLLOW-ON MAINTENANCE
Remove wheel chocks (TM 9-2320-347-10)
END OF TASK
END OF WORK PACKAGE
0172-3/(4 blank)