HYDRAULIC GENERATOR OIL COOLING FAN DOES NOT OPERATE PROPERLY
HYDRAULIC GENERATOR OIL COOLING FAN DOES NOT OPERATE PROPERLY - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 2 Page Navigation
  579    580    581    582    583  584  585    586    587    588    589  
img
DRAFT
TM 5-4210-249-13&P-2
0172
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT00731
WARNING
ICON 3 AND 18
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle. Jewelry can catch on equipment and cause serious injury. Jewelry
and tools may short across electrical circuits and cause damage to equipment, or
severe burns or electrical shock to personnel.
Use caution when working around hydraulic generator oil cooler fan. Fan may
operate without warning. Failure to comply may result in serious injury to
personnel.
Step 1.
Check if 30 amp circuit breaker is tripped.
If circuit breaker is tripped, reset circuit breaker.
Step 2.
Turn battery disconnect to ON position (WP 0007). Check for 22 to 28 VDC on wire
1138 (red) at hydraulic oil cooler fan connector.
If there are not 22 to 28 VDC repair wire 1138 (red) if
repairable (TM 9-2320-325-14&P), or replace body air condenser wire
harness (WP 0436).