DRAFT
TM 5-4210-249-13&P-2
0165
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT03917A
Step 6.
Check for continuity across white wire from cord reel receptacle box, white wire
connection, to a known good ground.
If there is no continuity, go to Step 20.
Step 7.
Check for continuity across green wire from cord reel receptacle box, green wire
connection, to a known good ground.
If there is no continuity, go to Step 22.
TFFT03918
NOTE
Circuit breaker may be in ON position when tripped. To make sure circuit breaker is not
tripped, reset circuit breaker by switching it to the OFF position, then back to the ON
position.
Step 8.
Check if circuit breakers 2 or 4 have been tripped.
If circuit breakers have been tripped, reset circuit breakers and go to Step 9.
0165-5