120-VOLT RECEPTACLES DO NOT OPERATE - Continued
120-VOLT RECEPTACLES DO NOT OPERATE - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 2 Page Navigation
  476    477    478    479    480  481  482    483    484    485    486  
img
DRAFT
TM 5-4210-249-13&P-2
0164
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT03844
Step 3.
Remove jumperwire and check for continuity from black wire at non-operating
receptacle terminal to ground.
If there is continuity, repair short to ground in black wire between receptacle
and circuit breaker if repairable (TM 9-2320-325-14&P), or replace power
cord between circuit breaker and receptacle (WP 0361).
Step 4.
Check for continuity from white wire at non-operating receptacle terminal to ground.
If there is no continuity, repair white wire between receptacle and circuit
breaker if repairable (TM 9-2320-325-14&P), or replace power cord
between circuit breaker and receptacle (WP 0361).
Step 5.
Check for continuity from green wire at non-operating receptacle terminal to ground.
If there is no continuity, repair green wire between receptacle and circuit
breaker if repairable (TM 9-2320-325-14&P), or replace power cord
between circuit breaker and receptacle (WP 0361).
0164-4