DRAFT
TM 5-4210-249-13&P-2
0160
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT03898
Step 12.
Check battery equalizer wire connections for loose and corroded terminals.
If connections are loose or corroded, clean and tighten connections or
replace battery equalizer (WP 0367).
Step 13.
Connect batteries (TM 9-2320-325-14&P). Check for 10 to 14 VDC between wire 1663
at 12 VDC connection on battery equalizer and a known good ground.
a.
If 10 to 14 VDC are present, repair wire 1663 between battery equalizer
and Battery Direct 12 VDC terminal block in Power Distribution Panel if
repairable (TM 9-2320-325-14&P), or replace wire 1663 (WP 0368).
b.
If 10 to 14 VDC are not present, repair wire 1663 between 12 VDC
connection on battery equalizer and battery pack if
repairable (TM 9-2320-325-14&P), or replace wire 1663 (WP 0368).
Step 14.
Disconnect batteries (TM 9-2320-325-14&P). Check wire connections at battery
equalizer for loose and corroded terminals.
a.
If connections are loose or corroded, clean and tighten connections or
replace battery equalizer (WP 0367).
b.
If connections are not loose or corroded, repair wire 1663 between 12
VDC connection on battery equalizer and battery pack if
repairable (TM 9-2320-325-14&P), or replace wire 1663 (WP 0368).
END OF TASK
0160-10