DRAFT
TM 5-4210-249-13&P-2
0160
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT03895
Step 4.
Check if cab power distribution wire harness handheld radio battery charger power cord
connector is securely connected on non-operating handheld radio battery charger.
If power cord is not securely connected, reconnect power cord (WP 0406).
WARNING
ICON 3
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle. Jewelry can catch on equipment and cause serious injury. Jewelry
and tools may short across electrical circuits and cause damage to equipment, or
severe burns or electrical shock to personnel.
Step 5.
Disconnect cab power distribution wire harness handheld radio battery charger power
cord connector from non-operating handheld radio battery charger. Check for 10 to 14
VDC between wire 2074 (red) at cab power distribution wire harness handheld radio
battery charger power cord connector and a known good ground.
If 10 to 14 VDC are not present, repair wire 2074 in cab power distribution
wire harness if repairable (TM 9-2320-325-14&P), or replace cab power
distribution wire harness and block (WP 0441).
0160-5