12-VOLT HANDHELD RADIO BATTERY CHARGER(S) DOES NOT OPERATE (PERSONNEL CAB) - Continued
12-VOLT HANDHELD RADIO BATTERY CHARGER(S) DOES NOT OPERATE (PERSONNEL CAB) - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 2 Page Navigation
  436    437    438    439    440  441  442    443    444    445    446  
img
DRAFT
TM 5-4210-249-13&P-2
0160
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT03897
Step 10.
Check for 10 to 14 VDC between wire 1663 at Battery Direct 12 VDC terminal block in
Power Distribution Panel and a known good ground.
If 10 to 14 VDC are present, repair wire 1663 in cab power distribution wire
harness if repairable (TM 9-2320-325-14&P), or replace cab power
distribution wire harness and block (WP 0441).
Step 11.
Disconnect batteries (TM 9-2320-325-14&P). Check wire connections at Battery Direct
12 VDC terminal block in Power Distribution Panel for loose and corroded terminals.
If connections are loose or corroded, clean and tighten connections or
replace Battery Direct 12 VDC terminal block in Power Distribution
Panel (WP 0429).