TANK DRAIN INDICATOR DOES NOT ILLUMINATE (PUMP OPERATOR'S PANEL) - Continued
TANK TO PUMP INDICATOR DOES NOT ILLUMINATE (CAB)

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 2 Page Navigation
  200    201    202    203    204  205  206    207    208    209    210  
img
DRAFT
TM 5-4210-249-13&P-2
0141
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT03563
Step 4.
Turn battery disconnect switch to ON position (WP 0007). Put WATER TANK DRAIN
switch to OPEN position (WP 0004). Check for 22 to 28 VDC between pump operator's
panel wire harness wire 4053 (brown) at WATER TANK DRAIN indicator and a known
good ground. Put pump operator's panel WATER TANK DRAIN switch to CLOSED
position (WP 0004). Turn battery disconnect switch to OFF position (WP 0007).
Connect pump house wire harness water tank drain control valve connector.
a.
If 22 to 28 VDC are present, replace pump operator's panel WATER
TANK DRAIN indicator (WP 0326).
b.
If 22 to 28 VDC are not present, repair wire 4053 in pump operator's
panel wire harness if repairable (TM 9-2320-325-14&P), or replace
pump operator's panel wire harness (WP 0459).
END OF TASK
FOLLOW-ON MAINTENANCE
Remove wheel chocks (TM 9-2320-347-10)
END OF TASK
END OF WORK PACKAGE
0141-5/(6 blank)