DRAFT
TM 5-4210-249-13&P-2
FIELD LEVEL MAINTENANCE
TANK DRAIN INDICATOR DOES NOT ILLUMINATE (PUMP OPERATOR'S PANEL)
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Tools and Special Tools
References (continued)
Lead Set, Test (WP 0622, Item 21)
WP 0326
Tool Kit, General Mechanic's: Automotive
WP 0327
(WP 0622, Item 27)
WP 0459
WP 0540
References
Equipment Conditions
TM 9-2320-325-14&P
WP 0004
Water pump engine OFF (WP 0022)
WP 0007
Engine OFF (TM 9-2320-347-10)
WP 0122
Wheels chocked (TM 9-2320-347-10)
WP 0325
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TANK DRAIN INDICATOR DOES NOT ILLUMINATE (PUMP OPERATOR'S PANEL)
NOTE
Do not operate WATER TANK DRAIN switch except when noted in Step 1. If water tank
drain valve is operated when water tank is filled, water will be discharged from water tank
uncontrolled. Water tank drain valve is not activated in Step 1.
Step 1 will ensure that water tank drain system is operating properly or if fault exists in
lamp, indicator, or wires leading to indicator.
0141-1