PUMP COOLER INDICATOR DOES NOT ILLUMINATE (PUMP OPERATOR'S PANEL) - Continued
PUMP ENGINE RUNNING INDICATOR NOT ILLUMINATED WHEN WATER PUMP ENGINE IS RUNNING

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 2 Page Navigation
  161    162    163    164    165  166  167    168    169    170    171  
img
DRAFT
TM 5-4210-249-13&P-2
0136
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT02567
Step 4.
Turn battery disconnect switch to ON position (WP 0007). Put pump operator's panel
PUMP COOLER switch to ON position (WP 0004). Check for 22 to 28 VDC between
wire 4037 (orange) at pump operator's panel wire harness PUMP COOLER indicator
terminal, and a known good ground.
a.
If 22 to 28 VDC are present, replace pump operator's panel PUMP
COOLER indicator (WP 0326).
b.
If 22 to 28 VDC are not present, repair wire 4037 in pump operator's
panel wire harness if repairable (TM 9-2320-325-14&P), or replace
pump operator's panel wire harness (WP 0459).
END OF TASK
FOLLOW-ON MAINTENANCE
Remove wheel chocks (TM 9-2320-347-10)
END OF TASK
END OF WORK PACKAGE