DRAFT
TM 5-4210-249-13&P-2
0135
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT02482
Step 3.
Check for continuity across cab pump control wire harness wire 1023 (black) from
PUMP COOLER OPEN indicator terminal connector to a known good ground.
If there is no continuity, repair wire 1023 in cab pump control wire harness if
repairable (TM 9-2320-325-14&P), or replace cab pump control wire
harness (WP 0443).
Step 4.
Disconnect jumperwire 2768 (white) from PUMP COOLER OPEN indicator terminals.
Check for continuity across jumperwire 2768 (white) from terminal to terminal.
a.
If there is continuity, replace cab PUMP COOLER OPEN
indicator (WP 0313).
b.
If there is no continuity, repair or replace jumperwire 2768 if repairable
(TM 9-2320-325-14&P), or replace cab pump control wire
harness (WP 0443).
END OF TASK
FOLLOW-ON MAINTENANCE
Remove wheel chocks (TM 9-2320-347-10)
END OF TASK
END OF WORK PACKAGE