PUMP ENGINE RUNNING INDICATOR NOT ILLUMINATED WHEN WATER PUMP ENGINE IS RUNNING - Continued
PUMP ENGINE RUNNING INDICATOR NOT ILLUMINATED WHEN WATER PUMP ENGINE IS RUNNING - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 2 Page Navigation
  164    165    166    167    168  169  170    171    172    173    174  
img
DRAFT
TM 5-4210-249-13&P-2
0137
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT04631
Step 4.
Stop water pump engine (WP 0022). Turn battery disconnect switch to OFF
position (WP 0007). Remove lamp from pump operator's panel PUMP ENGINE
RUNNING indicator (WP 0327). Check for continuity across lamp.
If continuity is not present, replace lamp (WP 0327).
TFFT04632
Step 5.
Install lamp in pump operator's panel PUMP ENGINE RUNNING indicator (WP 0327).
Open pump operator's panel housing (WP 0325). Check for continuity across wire
3895 (black) terminal from pump operator's panel PUMP ENGINE RUNNING indicator
to a known good ground.
If continuity is not present, repair wire 3895 in pump operator's panel wire
harness if repairable (TM 9-2320-325-14&P), or replace pump operator's
panel wire harness (WP 0459).
0137-3