FOAM SYSTEM INDICATOR DOES NOT ILLUMINATE (PUMP OPERATOR'S PANEL) - Continued
PUMP COOLER OPEN INDICATOR DOES NOT ILLUMINATE (CAB)

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 2 Page Navigation
  154    155    156    157    158  159  160    161    162    163    164  
img
DRAFT
TM 5-4210-249-13&P-2
0134
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT02512
Step 4.
Turn battery disconnect switch to ON position (WP 0007). Put pump operator's panel
FOAM SYSTEM switch to ON position (WP 0004). Check for 22 to 28 VDC between
wire 2830 (red) at pump operator's panel FOAM SYSTEM indicator terminal and a
known good ground.
a.
If 22 to 28 VDC are present, replace FOAM SYSTEM
indicator (WP 0327).
b.
If 22 to 28 VDC are not present, repair wire 2830 in pump operator's
panel wire harness if repairable (TM 9-2320-325-14&P), or replace
pump operator's panel wire harness (WP 0459).
END OF TASK
FOLLOW-ON MAINTENANCE
Remove wheel chocks (TM 9-2320-347-10)
END OF TASK
END OF WORK PACKAGE
0134-5/(6 blank)