DO NOT MOVE APPARATUS WHEN LIGHT IS ON INDICATOR DOES NOT OPERATE PROPERLY - Continued
DO NOT MOVE APPARATUS WHEN LIGHT IS ON INDICATOR DOES NOT OPERATE PROPERLY - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 2 Page Navigation
  90    91    92    93    94  95  96    97    98    99    100  
img
DRAFT
TM 5-4210-249-13&P-2
0130
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT02982
Step 67.
Turn Service Drive Lights Off (TM 9-2320-347-10). Turn battery disconnect switch to
OFF position (WP 0007). Remove fuse FS 11 (WP 0401). Check for continuity across
fuse.
If there is no continuity, replace fuse FS 11 (WP 0401).
0130-47