WATER TANK LEVEL INDICATOR GAUGE DOES NOT OPERATE PROPERLY - Continued
WATER TANK LEVEL INDICATOR GAUGE DOES NOT OPERATE PROPERLY - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  1006    1007    1008    1009    1010  1011  1012    1013    1014    1015    1016  
img
.
DRAFT
TM 5-4210-249-13&P-1
0123
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT03885
Step 10.
Connect cab water level gauge wire harness connector to cab WATER LEVEL gauge.
Disconnect water level gauge auto fill control wire harness connector from pump
operator's panel WATER LEVEL gauge. Connect cab water level gauge wire harness
connector to pump operator's panel WATER LEVEL gauge auto fill wire harness
connector. Turn battery disconnect switch to ON position (WP 0007). Check if cab
WATER LEVEL gauge indicates correct water level in water tank.
a.
If cab WATER LEVEL gauge indicates correct water level in tank,
replace pump operator's panel WATER LEVEL gauge (WP 0339).
b.
If cab WATER LEVEL gauge does not indicate correct water level in
tank, replace personnel cab WATER LEVEL gauge (WP 0316).