WATER TANK LEVEL INDICATOR GAUGE DOES NOT OPERATE PROPERLY - Continued
WATER TANK LEVEL INDICATOR GAUGE DOES NOT OPERATE PROPERLY - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  1005    1006    1007    1008    1009  1010  1011    1012    1013    1014    1015  
img
.
DRAFT
TM 5-4210-249-13&P-1
0123
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT03884
WARNING
ICON 3
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle. Jewelry can catch on equipment and cause serious injury. Jewelry
and tools may short across electrical circuits and cause damage to equipment, or
severe burns or electrical shock to personnel.
Step 9.
Turn battery disconnect switch to OFF position (WP 0007). Open pump operator's
panel housing (WP 0325). Disconnect cab water level gauge wire harness connector
from pump operator's panel WATER LEVEL gauge. Remove cab instrument panel
B (WP 0311). Disconnect cab water level gauge wire harness connector from cab
WATER LEVEL gauge. With a test lead set, check for continuity across cab water level
gauge wire harness from pump operator's panel WATER LEVEL gauge connector,
terminal 1 to cab WATER LEVEL gauge connector, terminal 1. Note reading. Repeat
continuity checks for terminals 2 to 2, 3 to 3, 4 to 4, 5 to 5, 6 to 6, and 7 to 7.
If there is no continuity for any pair of terminals, replace cab water tank level
gauge wire harness (WP 0444).
0123-6