DRAFT
TM 5-4210-249-13&P-1
0119
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 4.
While an assistant puts pump operator's panel TANK TO PUMP switch to CLOSED
position (WP 0004), check if tank-to-pump valves operate to closed position.
If tank-to-pump valves do not operate to closed position, go to Step 10.
Step 5.
Release pump operator's panel TANK TO PUMP switch (WP 0004). While an assistant
puts cab TANK TO PUMP switch to open position (WP 0004), check if tank-to-pump
valves operate to open position.
If tank-to-pump valves do not operate to open position, go to Step 8.
Step 6.
While an assistant puts cab TANK TO PUMP switch to closed position (WP 0004),
check if tank-to-pump valves operate to closed position.
If tank-to-pump valves operate to closed position, fault corrected.
0119-3