TANK FILL & RE-CIRCULATING VALVE DOES NOT OPERATE PROPERLY - Continued
TANK FILL & RE-CIRCULATING VALVE DOES NOT OPERATE PROPERLY - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  924    925    926    927    928  929  930    931    932    933    934  
img
. .
DRAFT
TM 5-4210-249-13&P-1
0118
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT03434
Step 8.
Connect valve control wire harness connector to tank fill & re-circulating line valve
motor. Disconnect valve control wire harness connectors from DRIVER MAIN INLET
valve control. Connect tank fill & re-circulating line valve control wire harness connector
to DRIVER MAIN INLET valve control. Turn battery disconnect switch to ON
position (WP 0007). While an assistant pushes pump operator's panel DRIVER MAIN
INLET valve control OPEN and CLOSE buttons (WP 0004), check if tank fill & re-
circulating line valve operates.
a.
If tank fill & re-circulating line valve operates, reconnect valve control
wire harness connectors to original positions and replace TANK FILL &
RE-CIRCULATING LINE valve control (WP 0418).
b.
If tank fill & re-circulating line valve does not operate, reconnect valve
control wire harness connectors to original positions and replace tank
fill & re-circulating line valve motor (WP 0388).