SYSTEM WILL NOT BUILD OR HOLD AIR PRESSURE DURING BLOW-OUT PROCEDURE - Continued
SYSTEM WILL NOT BUILD OR HOLD AIR PRESSURE DURING BLOW-OUT PROCEDURE - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  909    910    911    912    913  914  915    916    917    918    919  
img
.
DRAFT
TM 5-4210-249-13&P
0117
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT04826
Step 3.
While an assistant maintains 50 PSI (345 kPa) on PUMP DISCHARGE digital
gauge (WP 0004). Check if air can be heard escaping from No. 1 DRIVER SIDE
DISCHARGE.
If air can be heard escaping from No. 1 DRIVER SIDE DISCHARGE,
repair (WP 0387) or replace No. 1 Driver Side Discharge Valve (WP 0485).
Step 4.
Check if air can be heard escaping from No. 2 DRIVER SIDE DISCHARGE
If air can be heard escaping from No. 2 DRIVER SIDE DISCHARGE,
repair (WP 0387) or replace No. 2 Driver Side Discharge Valve (WP 0486).
0117-3