SYSTEM WILL NOT BUILD OR HOLD AIR PRESSURE DURING BLOW-OUT PROCEDURE - Continued
SYSTEM WILL NOT BUILD OR HOLD AIR PRESSURE DURING BLOW-OUT PROCEDURE - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  910    911    912    913    914  915  916    917    918    919    920  
img
DRAFT
TM 5-4210-249-13&P
0117
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT04827
Step 5.
Check if air can be heard escaping from No. 3 PASSENGER SIDE DISCHARGE.
If air can be heard escaping from No. 3 PASSENGER SIDE DISCHARGE,
repair (WP 0387) or replace No. 3 Passenger Side Discharge
Valve (WP 0487).
Step 6.
Check if air can be heard escaping from No. 4 PASSENGER SIDE DISCHARGE
If air can be heard escaping from No. 4 PASSENGER SIDE DISCHARGE,
repair (WP 0387) or replace No. 4 Passenger Side Discharge
Valve (WP 0488).
0117-4