PUMP COOLER VALVE DOES NOT OPERATE PROPERLY - Continued
PUMP COOLER VALVE DOES NOT OPERATE PROPERLY - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  843    844    845    846    847  848  849    850    851    852    853  
img
DRAFT
TM 5-4210-249-13&P-1
0114
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT03476
Step 39.
Remove personnel cab panel C (WP 0311). Disconnect cab instrument panel cab roof
wire harness connector. With a test lead set, check for continuity across wire 1640
(black) from roof, bumper, and pump cooler junction box to cab roof wire harness
connector terminal C.
a.
If there is continuity, repair wire 1640 in cab instrument panel wire
harness if repairable (TM 9-2320-325-14&P), or replace cab instrument
panel wire harness (WP 0440).
b.
If there is no continuity, repair wire 1640 in cab roof wire harness if
repairable (TM 9-2320-325-14&P), or replace cab roof wire
harness (WP 0442).
0114-27