NO. 2 DISCHARGE VALVE (DRIVER SIDE) DOES NOT OPERATE PROPERLY - Continued
NO. 2 DISCHARGE VALVE (DRIVER SIDE) DOES NOT OPERATE PROPERLY - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  756    757    758    759    760  761  762    763    764    765    766  
img
.
DRAFT
TM 5-4210-249-13&P-1
0110
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT02641
NOTE
Ensure batteries are fully charged before performing Step 1.
Step 1.
Turn battery disconnect switch to ON position (WP 0007). Check if pump operator's
panel NO. 2 DRIVER SIDE DISCHARGE valve control display illuminates.
If display is not illuminated, go to Step 17.
0110-2