MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT03873
Step 13.
Remove four screws and bezel from pump operator's panel DRIVER SIDE PRE-
CONNECT A valve control. Check for signs of water and moisture damage.
If DRIVER SIDE PRE-CONNECT A valve control shows evidence of water
and moisture damage, replace DRIVER SIDE PRE-CONNECT A valve
control (WP 0417).
Step 14.
Install bezel and four screws on DRIVER SIDE PRE-CONNECT A valve control.
Remove driver side pre-connect A valve (WP 0495) and inspect it for binding, damage,
a.
If driver side pre-connect A valve is free from binding, damage, and
contamination, reinstall valve (WP 0495) and replace driver side pre-
connect A valve motor and drive assembly (WP 0388).
b.
If driver side pre-connect A valve is binding, damaged, and/or
contaminated, replace driver side pre-connect A valve (WP 0495).