DRIVER MAIN INLET VALVE DOES NOT OPERATE PROPERLY - Continued
DRIVER SIDE PRE-CONNECT A VALVE DOES NOT OPERATE PROPERLY

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  706    707    708    709    710  711  712    713    714    715    716  
img
DRAFT
TM 5-4210-249-13&P-1
0106
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT03426
Step 15.
Disconnect pump house wire harness pump house power distribution wire harness
connector DP2. With a test lead set, check for 22 to 28 VDC between pump house
power distribution wire harness wire 4082 (gray) at connector DP2, terminal M and a
known good ground.
a.
If 22 to 28 VDC are not present, repair wire 4082 in pump house power
distribution wire harness if repairable (TM 9-2320-325-14&P), or
replace pump house power distribution wire harness and block
(WP 0457).
b.
If 22 to 28 VDC are not present, repair wire 4082 (gray) in pump house
wire harness if repairable (TM 9-2320-325-14&P), or replace pump
house wire harness (WP 0458).
END OF TASK
FOLLOW-ON MAINTENANCE
Remove wheel chocks (TM 9-2320-347-10)
END OF TASK
END OF WORK PACKAGE
0106-12