FOAM NOT DELIVERED FROM GROUND SWEEPS - Continued
FOAM NOT DELIVERED FROM GROUND SWEEPS - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  560    561    562    563    564  565  566    567    568    569    570  
img
. .
DRAFT
TM 5-4210-249-13&P-1
0099
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT03394
Step 8.
Remove pump house panel S (WP 0540). Put cab FOAM SYSTEM switch to off
position (WP 0004). Put GROUND SWEEPS switch to off position (WP 0004). Check
air lines from FOAM B shutoff valve control manifold to foam system flow control
manifold for leaks, kinks, or damage.
If air lines are not free from leaks, kinks, or damage, replace damaged air
lines (WP 0567).
Step 9.
Check lines from GROUND SWEEPS FOAM B foam system flow control manifold to
ground sweeps foam B multi-metering valve cylinder for leaks, kinks, or damage.
If air lines are not free from leaks, kinks, or damage, replace damaged air
lines (WP 0567).