FOAM NOT DELIVERED FROM ALL SYSTEMS (BUMPER TURRET, GROUND SWEEPS, AND MANUAL METERING CONTROLS) OR SYSTEM DOES NOT SHUT OFF - Continued
FOAM NOT DELIVERED FROM ALL SYSTEMS (BUMPER TURRET, GROUND SWEEPS, AND MANUAL METERING CONTROLS) OR SYSTEM DOES NOT SHUT OFF - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  465    466    467    468    469  470  471    472    473    474    475  
img
. .
DRAFT
TM 5-4210-249-13&P-1
0094
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT03710
Step 12.
Turn battery disconnect switch to OFF position (WP 0007). Open pump operator's
panel housing (WP 0325). While an assistant holds pump operator's panel FOAM
SYSTEM switch to OFF position (WP 0004), check for continuity across FOAM
SYSTEM switch from, terminal wire 2816 (red) to terminal wire 2831 (blue).
If there is no continuity, replace pump operator's panel FOAM SYSTEM
switch (WP 0330).
TFFT03711
Step 13.
Disconnect cab pump control wire harness cab power distribution wire harness
connector. Check for continuity across cab power distribution wire harness wire 2831
(blue) from cab power distribution block relay 10, terminal 1 to cab pump control wire
harness cab power distribution wire harness connector, terminal 18.
If there is no continuity, repair wire 2831 in cab power distribution wire
harness if repairable (TM 9-2320-325-14&P), or replace cab power
distribution wire harness and block (WP 0441).
0094-9